<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15398</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Important!
Visually inspect the drum.
If drum is EMPTY, click MEDIA CLEAR.
Otherwise, click RESUME.
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Open the front or top door of the machine and check inside the machine. If the drum is
empty, close the door and click "MEDIA CLEAR". If the drum is NOT empty, close the door
and click "RESUME".
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
Make sure the customer visually inspect the drum. In addition, remove any flyoff media
in the machine.
</text></DescriptionText>
</ServiceInformation>
<Cause>
While clearing a previous error, the operator clicked "MEDIA CLEAR" without manually remove the
carrier or plate. This caused the firmware to think that the drum is empty yet there is actually
something on the drum.
</Cause>
<Cause>
Mis-use of the "proof mode" command.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/proof_mode.xml</LinkAddress><LinkTitle>Command: proof mode</LinkTitle></Link>
<Link><LinkAddress>../nvs/proof_cal_dvct.xml</LinkAddress><LinkTitle>NVS: proof dvct</LinkTitle></Link>
<Link><LinkAddress>../nvs/plate_loc_state_status.xml</LinkAddress><LinkTitle>NVS: plate_loc status</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:08 2008 PST
</Updated>
<Links>
</Links>
</Error>